摘    要:结合某海上风电场桩基工程中的大直径超长钢管桩抗拔承载力研究,利用离心模拟技术,初步推求得出荷载-位移的关系曲线(即Q-S曲线),并与现场抗拔试验成果得出的Q-S曲线进行了比较,分析两者加载方式和加载速率的不同对Q-S曲线的影响。结果发现,上拔力的加载速率较快,求得的单桩抗拔极限承载力偏高。

关 键 词:抗拔桩  离心模拟  Q-S曲线  加载方式  加载速率  抗拔极限承载力  
收稿时间:2011-10-21

Centrifugal Model Test on the Vertical Uplift Bearing Capacity of Single Pile
REN Guo-feng , XU Guang-ming , GU Xing-wen. Centrifugal Model Test on the Vertical Uplift Bearing Capacity of Single Pile[J]. Journal of Yangtze River Scientific Research Institute, 2012, 29(1): 91-94
Authors:REN Guo-feng    XU Guang-ming    GU Xing-wen
Affiliation:1.Nanjing Hydraulic Research Institute, Nanjing210024, China;2.State Key Laboratory of Hydrology Water Resources and Hydraulic Engineering, Nanjing210029, China
Abstract:To assist the design of pile foundation of an offshore wind farm,centrifuge modeling is performed to determine the uplift bearing capacity of single ultra-long steel pipe-pile of large diameter by which the wind turbine foundation is constituted.Curve of load versus displacement(Q-S curve) deducted from the results of centrifuge model test are compared with that from prototype uplift capacity test.The effect of loading manner and loading rate on the ultimate uplift bearing capacity is discussed.It is shown by comparison that the value of ultimate uplift bearing capacity of single pile from centrifuge test is greater than that obtained from prototype test.As higher rate usually mobilizes higher strength,a higher loading rate in the centrifuge model test is regarded as the cause of the difference between two test results.
Keywords:uplift pile  centrifuge modeling  Q-S curve  loading manner  loading rate  ultimate uplift bearing capacity