首页 | 本学科首页   官方微博 | 高级检索  
     


Automatic moment segmentation and peak detection analysis of heart sound pattern via short-time modified Hilbert transform
Authors:Shuping Sun  Zhongwei Jiang  Haibin Wang  Yu Fang
Affiliation:1. Department of Mechanical Engineering, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi, Japan;2. School of Electrical and Information Engineering, Xihua University, Chengdu 610039, China
Abstract:This paper proposes a novel automatic method for the moment segmentation and peak detection analysis of heart sound (HS) pattern, with special attention to the characteristics of the envelopes of HS and considering the properties of the Hilbert transform (HT). The moment segmentation and peak location are accomplished in two steps. First, by applying the Viola integral waveform method in the time domain, the envelope (ET) of the HS signal is obtained with an emphasis on the first heart sound (S1) and the second heart sound (S2). Then, based on the characteristics of the ET and the properties of the HT of the convex and concave functions, a novel method, the short-time modified Hilbert transform (STMHT), is proposed to automatically locate the moment segmentation and peak points for the HS by the zero crossing points of the STMHT. A fast algorithm for calculating the STMHT of ET can be expressed by multiplying the ET by an equivalent window (WE). According to the range of heart beats and based on the numerical experiments and the important parameters of the STMHT, a moving window width of N = 1 s is validated for locating the moment segmentation and peak points for HS. The proposed moment segmentation and peak location procedure method is validated by sounds from Michigan HS database and sounds from clinical heart diseases, such as a ventricular septal defect (VSD), an aortic septal defect (ASD), Tetralogy of Fallot (TOF), rheumatic heart disease (RHD), and so on. As a result, for the sounds where S2 can be separated from S1, the average accuracies achieved for the peak of S1 (AP1), the peak of S2 (AP2), the moment segmentation points from S1 to S2 (AT12) and the cardiac cycle (ACC) are 98.53%, 98.31% and 98.36% and 97.37%, respectively. For the sounds where S1 cannot be separated from S2, the average accuracies achieved for the peak of S1 and S2 (AP12) and the cardiac cycle ACC are 100% and 96.69%.
Keywords:HS  HS moment segmentation  Peak location  ET  STMHT  WE
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号