摘    要:通过对1榀柱中内置型钢和1榀梁柱均内置型钢的预应力型钢混凝土框架的竖向反复荷载试验, 研究预应力型钢混凝土框架的破坏机制、滞回特性、延性、刚度和耗能等性能。结果表明:预应力型钢混凝土框架梁是梁铰破坏机制,极限状态时 “拱效应”提高了框架梁的承载能力;预应力型钢混凝土框架梁滞回曲线饱满,变形恢复能力小于普通预应力混凝土框架梁;预应力型钢混凝土框架梁位移延性系数均值为4.8,普通预应力混凝土框架梁的为4.18,均有较好的延性;等效黏滞阻尼系数介于0.258~0.323之间,说明2个试件破坏时截面具有良好的耗能能力;参数分析表明,试件延性系数受含钢率影响不大,随内置型钢截面高度与梁截面高度比值增大而增大。

关 键 词:拟静力试验    竖向地震作用    预应力  抗震性能  型钢混凝土结构  

Experimental study on seismic performance of prestressed steel reinforced concrete frame structure under vertical reversed loading
GAO Feng,XIONG Xueyu.Experimental study on seismic performance of prestressed steel reinforced concrete frame structure under vertical reversed loading[J].Journal of Building Structures,2013,34(7):62-71.
Authors:GAO Feng  XIONG Xueyu
Affiliation:1.School of Civil Engineering and Architecture, University of Jinan, Jinan 250022, China; ; 2.Department of Building Engineering, Tongji University, Shanghai 200092, China
Abstract:A study was conducted on the vertical seismic behaviors of one prestressed steel reinforced concrete frame with steel in columns only and one frame with steel in beams and columns. The seismic behavior of prestressed steel reinforced concrete frames, such as the failure patterns, hysteresis loops, displacement ductility, stiffness and energy dissipation was studied. It is shown that the failure patterns are beam hinge failure and arching action can enhance the ultimate load of the frame beam. The hysteretic loops of the prestressed steel reinforced concrete frame beam is plumer and the deformation recovery is less than that of the frame beam without steel. The average displacement ductility coefficient of prestressed steel reinforced concrete frame beam is 4.8 and prestressed reinforced concrete frame beam is 4.18, indicating that two frame beams have good ductility. The equivalent viscous damping coefficient is about 0.258 to 0.323, indicating that two frame beams have good energy dissipation capacity. The ductility factor is not significantly affected by the steel ratio,but it increases as the ratio of depth of steel to depth of the beam increases.
Keywords:steel reinforced concrete structure  prestressing  vertical seismic action  quasi-static test  seismic performance
本文献已被 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号