首页 | 本学科首页   官方微博 | 高级检索  
     


Frequency limitations and optimal step size for the two-point central difference derivative algorithm with applications to human eye movement data
Authors:A T Bahill  J D McDonald
Affiliation:Biomedical Engineering Program, Department of Electrical Engineering, Carnegie-Mellon University;
Abstract:There are many algorithms for calculating derivatives. The two-point central difference algorithm is the simplest. Besides simplicity, the two most important characteristics of this algorithm are accuracy and frequency response. The frequency content of the data prescribes a lower limit on the sampling rate. The smoothness and accuracy of the data determine the optimal step size. We discuss the low-pass filter characteristics of this algorithm and derive the optimal step size for two types of human eye movement data. To calculate the velocity of fast (saccadic) eye movements, the algorithm should have a cutoff frequency of 74 Hz. For typical slow (smooth pursuit) eye movements, a step size of 25 or 50 ms is optimal.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号