引用本文:全桂香,严金龙. 微波消解-阳极溶出伏安法测定皮革中镉含量[J]. 化工时刊, 2007, 21(9): 36-37
作者姓名:全桂香  严金龙
作者单位:盐城工学院化学与生物工程学院,江苏,盐城,224003;盐城工学院化学与生物工程学院,江苏,盐城,224003
摘    要:用微波消解皮革试样,在CH3COOH-CH3COONa底液中,用阳极溶出伏安法测定消解液中镉元素含量,方法的加标回收率为91.0%~101.0%,相对标准偏差为5.2%。

关 键 词:  微波消解  阳极溶出伏安法
收稿时间:2007-07-11
修稿时间:2007-07-11

Determination of Cadmium in Leather by Microwave Digestion - Anodic Stripping Voltammetry
Quan Guixiang,Yan Jinlong. Determination of Cadmium in Leather by Microwave Digestion - Anodic Stripping Voltammetry[J]. Chemical Industry Times, 2007, 21(9): 36-37
Authors:Quan Guixiang  Yan Jinlong
Affiliation:School of Chemical and Biological Engineering, Yaneheng Institute of Technology, Jiangsu Yancheng 224003
Abstract:The sample was digested by means of microwave method, the contents of cadmium in leather was determinate by anodie stripping square wave voltammetry in CH3COOH - CH3COONa buffer solution. The condition of microwave digestion were optimized. The RSD was 5.2%; the recovery tested by standard addition method were 91.0% - 101.0%.