KDONAr-10000/3500/350型空分设备调试总结
引用本文:李玉珍.KDONAr-10000/3500/350型空分设备调试总结[J].深冷技术,2012(3):25-27.
作者姓名:李玉珍
作者单位:河南豫光金铅股份有限公司,河南省济源市荆梁南街1号454650
摘    要:在KDONAr-10000/3500/350型空分设备调试过程中,发生了多起设备故障,影响了空分设备的正常投运。简介空分设备的建设过程和主要产品指标,详细介绍调试过程中发生的设备故障、原因分析过程和处理措施。

关 键 词:空分设备  调试  总结

Summaries of debugging of Model KDONAr-10000/3500/350 air separation plant
Li Yuzhen.Summaries of debugging of Model KDONAr-10000/3500/350 air separation plant[J].Cryogenic Technology,2012(3):25-27.
Authors:Li Yuzhen
Affiliation:Li Yuzhen ( Henan Yuguang Gold and Lead Co. , Ltd. , 1# South Jingliang Street, Jiyuan 454650, Henan, P. R. China )
Abstract:Several equipment troubles occurred during debugging of Model KDONAr-lO000/3500/350 air separation plant, which impaired the normal commissioning of the air separation plant. The construction process of air separation plant and main product indicators are briefed, and the equipment troubles occurred during the debugging process, the analysis of their causes and the treatment measures are detailed.
Keywords:Air separation plant  Debugging  Summaries