摘    要:论述了电气火灾产生的主要原因,简述了电气火灾监控系统的组成、功能、设置原则及设计方法等。建议电气火灾监控系统的设计应充分考虑低压配电系统的特性,应以线路漏电检测和报警为主,并在配电设备和线路的适当部位(如变压器、电缆竖井内等)增加温度监控器。

关 键 词:电气火灾  监控系统  剩余电流保护装置  低压配电系统

Establishment of Electric Fire Monitoring System
CHEN Lei.Establishment of Electric Fire Monitoring System[J].Moder Architecture Electric,2011,2(2):43-45.
Authors:CHEN Lei
Affiliation:CHEN Lei(Civil Aviation and Safety Engineering College,Shenyang Institute of Aeronautical Engineering,Shenyang 110136,China)
Abstract:The causes of electric fire were analyzed.The component,function,set principles and design method of electric fire monitoring system were described.It was suggested that the characteristics of low voltage distribution system should be taken full account of the distribution line leakage test and alarm must be emphasized in the design of electric fire control system.The temperature detector can be put in the proper place of distribution line and equipment,such as transformer and cable shaft.