摘    要:雷电对电气系统中的配网危害十分严重,因此,采取有效的防雷、接地措施十分重要。就配电系统中线路和变压器的防雷、接地问题进行了分析,并提出了相应的应对措施,为设计和运行维护人员提供一定的参考。

关 键 词:配电线路  防雷  接地  避雷器  变压器

Lightning Protection and Grouding Method of Power Distribution Circuit
CHEN Yongchun.Lightning Protection and Grouding Method of Power Distribution Circuit[J].Moder Architecture Electric,2011,2(2):16-18.
Authors:CHEN Yongchun
Affiliation:CHEN Yongchun(Guangzhou Fanyu Power Supply Bureau,Guangzhou 511462,China)
Abstract:Lightning has great harm to power distribution grid in electric system,therefore,adopting effective lightning protection,grounding methods are very important.The lightning protection,grounding of line and transformer in power distribution system were analyzed,and related solving mothods were put forward.It could provide reference to maintence staff and designers.
Keywords:power distribution line  lightning protection  grounding  arrester  transformer  