首页 | 本学科首页   官方微博 | 高级检索  
     


A new method for determining the armature leakage reactance ofsynchronous machines
Authors:El-Serafi   A.M. Wu   J.
Affiliation:Dept. of Electr. Eng., Saskatchewan Univ., Saskatoon, Sask.;
Abstract:A method for determining the armature leakage reactance of synchronous machines is presented. In this method, the terminal voltage/armature current characteristic with the machine unloaded and unexcited is needed, together with the open-circuit characteristic of the machine. The armature leakage reactance is derived from these two curves using an iterative technique. The armature leakage reactances of five synchronous machines of different designs are obtained using this method. Their values are compared with those of the Potier reactance of these machines measured at various terminal voltages
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏