首页 | 本学科首页   官方微博 | 高级检索  
     

KDON-400Y/400Y型空分设备循环气系统带水的分析及处理
引用本文:杨胜春,余良彪.KDON-400Y/400Y型空分设备循环气系统带水的分析及处理[J].深冷技术,2001(6):39-41.
作者姓名:杨胜春  余良彪
作者单位:兰州市27支局46信箱55号,732750
摘    要:分析了KDON - 40 0Y/ 4 0 0Y型空分设备循环气系统带水的原因 ,对流程部分进行了相应改进 ,采用了新的加热工艺 ,使问题得到圆满解决

关 键 词:空分设备  换热器  堵塞  改造
文章编号:1009-9425(2001)06-0039-03
修稿时间:2001年8月22日

Analysis of circulating gas system carrying water in model KDON- 400Y/400Y air separation plant and solutions
Yang Sheng chun,Yu Liang biao.Analysis of circulating gas system carrying water in model KDON- 400Y/400Y air separation plant and solutions[J].Cryogenic Technology,2001(6):39-41.
Authors:Yang Sheng chun  Yu Liang biao
Abstract:The cause of the circulating gas system carrying water in modelKDON-400Y/400Y air separation plant is analyzed in the paper.In addition the process has been improved accordingly and a new heating technique adopted.Consequently satisfactory results are obtained.
Keywords:Heat  exchanger  Blocking  Transformation  Air  separation  plant