首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of H'(0.07) using the plastic scintillation pulse height weighting integration method
Authors:Li-ye Liu  Ji-zeng Ma
Affiliation:China Institute for Radiation Protection, P.O. Box 120, Taiyuan 030006, China.
Abstract:The pulse height weighting integration method for measuring H'(0.07) using a plastic scintillator has been developed through Monte Carlo simulations and laboratory tests. In order to design an optimal detector configuration, the parameters of input-window thickness and plastic scintillator thickness were investigated by EGS4 for their influences on the energy response for electrons. Based on the calculated deposited spectra in the plastic scintillator for electrons with various incident energies, a weighting function W(E), folded with the deposited energy spectra, was introduced in order to obtain a flat energy response in the low energy range. A constant response within +/-3% was confirmed, by calculation, for electrons with energy >0.15 MeV. In addition, a preliminary experiment was performed using three beta sources (90Sr-90Y, 147Pm, 204Tl) and the energy response within +/-6% for beta rays with the maximum energy >0.22 MeV was obtained. Some factors causing uncertainties in the measurements are also discussed in this article.
Keywords:
本文献已被 PubMed Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号