摘    要:采用生物氧化过滤的方法对地下水除铁进行了研究。探讨了滤柱生物除铁的影响机理。在进水Fe2+的质量浓度为4.3mg/L,pH值为6.4~6.6,水温为23~25℃,溶解氧的质量浓度为1.5mg/L,滤速为8m/h的条件下出水水质良好,出水Fe2+的质量浓度达到0.1mg/L以下。通过灭活试验和细菌计数等试验验证该滤柱在除铁中,生物氧化起主要作用。

关 键 词:地下水  生物除铁  细菌计数
文章编号:1009-2455(2006)02-0025-03
修稿时间:2005年9月23日

Verification of effect and mechanism of biological iron-removal from ground water
YU Jian,YU Li-e,REN Wen-hui.Verification of effect and mechanism of biological iron-removal from ground water[J].Industrial Water & Wastewater,2006,37(2):25-27.
Authors:YU Jian  YU Li-e  REN Wen-hui
Abstract:Iron-removal from ground water by biological oxidation filtration was studied.The influencing mechanism of the filter candle on biological iron-removal was discussed.Under the condition that the mass concentration of Fe2+ was 4.3 mg/L,the pH value of the raw water was 6.4-6.6,the water temperature was 23-25 ℃,the mass concentration of dissolved oxygen was 1.5 mg/L,the filter speed was 8 m/h,a good effluent quality was obtained,the mass concentration of Fe2+ in effluent water was below 0.1 mg/L.The inactivation experiment,bacteria counting experiment and some other experiments indicated that biological oxidation had a significant effect on iron-removal in the said filter candle.