首页 | 本学科首页   官方微博 | 高级检索  
     


Novel flow analysis of regenerator under oscillating flow with pulsating pressure
Authors:Kwanwoo Nam  Sangkwon Jeong
Affiliation:Cryogenic Engineering Laboratory, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejon 305-701, South Korea
Abstract:A new model for the oscillating flow combined with pulsating pressure in cryocooler regenerators is developed to overcome inaccuracy of the conventional flow model based on steady flow friction factor. The new model is based on two non-dimensional parameters and one-dimensional governing equations. One of the parameters is the oscillating flow friction factor represented by the amplitudes of the pressure drop and the flow rate. The idea of the other important parameter originates from a volume averaged continuity equation, which includes the characteristic of randomly oriented matrix geometry. This parameter is named as Breathing factor, which implies that the regenerator breathes against the main oscillating flow. Empirical correlations of the parameters are obtained for screen regenerators. It is revealed that the phase angles of the pressure drop and the mass flow rate in regenerators are well predicted by introduction of the Breathing factor.
Keywords:Friction factor   Oscillating flow   Phase angle   Volume-averaging   Regenerator   Cryocooler
本文献已被 ScienceDirect 等数据库收录!