摘    要:矿热炉耗电巨大,功率因数较低,无功损耗大,通过对各类无功补偿技术的分析,阐明了低压短网直接补偿的方式节能增产效果最好,并对国内各类短网补偿的执行开关的优劣进行了对比分析,提出了组合式开关是解决涌流及过电压问题的最优方案,同时对低压侧短网补偿与工艺结合的其他问题进行了分析。

关 键 词:矿热炉  短网补偿  无功补偿  节能

SUBMERGED ARC FURNACE REACTIVE COMPENSATION AND ITS OPTIMIZATION SCHEME
Zheng Yuanbin. SUBMERGED ARC FURNACE REACTIVE COMPENSATION AND ITS OPTIMIZATION SCHEME[J]. Ferro-alloys, 2011, 42(3): 25-27
Authors:Zheng Yuanbin
Affiliation:Zheng Yuanbin (Beijing Sinengda Energy Conservation Electricity Co.,Ltd.,Beijing 100000,China)
Abstract:The electricity consumption of submerged arc furnace is huge,the power factor is lower and reactive power is large.Through the analysis of various reactive power compensation technology,stated the energy-saving and production -increasing effect of low voltage short network direct compensation is the best.Furthermore,made a comparative analysis of the advantages and disadvantages of excute switch of domestic different short network compensation,put forward that combined switch is an optimization scheme to so...