首页 | 本学科首页   官方微博 | 高级检索  
     

变压吸附装置氢气损失的原因及措施
引用本文:李志越,李旭亮. 变压吸附装置氢气损失的原因及措施[J]. 化肥工业, 2005, 32(3): 28-30
作者姓名:李志越  李旭亮
作者单位:河南神马集团尼龙化工有限责任公司,平顶山,467013
摘    要:对变压吸附装置氢气损失情况及原因进行了分析。通过采取优化操作条件、更换程控阀以及改造氢气管网的放空系统等措施,使氢气的损失率由6.3%降为1.6%,取得了显著的经济效益。

关 键 词:变压吸附装置 氢气 原因 操作条件 放空系统 经济效益 程控阀 损失率

Cause for Hydrogen Loss from Pressure Swing Adsorber and Remedial Measures Taken
Li Zhyue,Li Xuliang. Cause for Hydrogen Loss from Pressure Swing Adsorber and Remedial Measures Taken[J]. Journal of the Chemical Fertilizer Industry, 2005, 32(3): 28-30
Authors:Li Zhyue  Li Xuliang
Affiliation:Li Zhyue and Li Xuliang
Abstract:An analysis is made of the loss of hydrogen from the pressure swing adsorber and its cause, and after taking measures to optimize the operating conditions, replace the program control valves and renovate the purge system of the hydrogen pipe network, the hydrogen loss decreases from 6.3% to 1.6%, and marked economic benefit is obtained.
Keywords:hydrogen recovery PSA