摘    要:本文分析了高温、多尘环境如冶金、火电等行业夏季环境下操作室温度对操作室内设施的影响因素并详细介绍了室内得热量的计算及对制冷设备的选择依据。

关 键 词:独立空调   得热量   太阳辐射   计算方法

Discussion in Provides the Air Conditioning to Opperating Room in High-Temperature and Dusty Surrordings
Wang Jingyang,Yuan Binyan,Hu Xiaoliang,Ning xiaofeng. Discussion in Provides the Air Conditioning to Opperating Room in High-Temperature and Dusty Surrordings[J]. Metal World, 2007, 0(6): 30-32
Authors:Wang Jingyang  Yuan Binyan  Hu Xiaoliang  Ning xiaofeng
Abstract:the article has analyzed the factor that the temperture of operating room affect ing device of opperating room in metallurgical industry and thermal power industry etc. in summer under high-temperature and dusty surrordings, and, thoroudingly introuduce the computational method about results in the quantity of heat and the base of selecting refrigeration equipment
Keywords:Independent air conditioning  Results in the quantity of heat  Solar radiation   Computational method