首页 | 本学科首页   官方微博 | 高级检索  
     


Conditions Affecting Bromate Formation During Ozonation of Bottled Water
Authors:Mitrakas Manassis  Simeonidis Constantinos
Affiliation:Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece. E-mail: manasis@vergina.eng.auth.gr
Abstract:Bromate concentration, ozone lifetime and ozone exposure (CT value) measured in bottled water in full-scale runs, were in good agreement to those measured in laboratory experiments. Ozone lifetime in bottled water was high enough to result in a CT value greater than 5 even for ozone dose as low as 0.1?mgO3/L, at a water pH of 7.6. Bromate was gradually formed during the ozone lifetime. Bormate formation and ozone exposure were significantly influenced by pH. In full-scale runs, an ozone dose of 0.15?mgO3/L at pH=7.6 resulted in a CT of 10.3 and a bromate concentration of 13.5?µg/L, while at pH=7.25 the values of CT and BrO3 ? were 12.6 and 9.6?µg/L, respectively. By decreasing further the pH to 6.8, an increase of CT value to 15.8 and a reduction of bromate to 5.5?µg BrO3 ?/L were observed. In addition, results in full-scale runs showed that ozone exposure and bromate concentrations were linearly related to ozone dose in the working range of 0.1 to 0.25?mgO3/L.
Keywords:Ozone  Bromate Formation  CT Value  Bottled Water  pH Effect
设为首页 | 免责声明 | 关于勤云 | 加入收藏