首页 | 本学科首页   官方微博 | 高级检索  
     

武钢60000m~3/h空分设备空冷塔激冷水分配器故障分析及处理
引用本文:周敦武 黄政明. 武钢60000m~3/h空分设备空冷塔激冷水分配器故障分析及处理[J]. 深冷技术, 2007, 0(4): 46-48
作者姓名:周敦武 黄政明
作者单位:武汉钢铁集团氧气有限责任公司,湖北省武汉市青山区白玉山430083
摘    要:介绍了60000m3/h空分设备空冷塔激冷水分配器故障现象和故障具体部位的确认过程;分析了激冷水分配器故障的原因,最后简述了预防措施。

关 键 词:大型空分设备  空气预冷系统  水分配器
修稿时间:2007-01-102007-04-12

Analysis and treatment of the fault with chilling water distributor of air cooling tower in a 60000m^3/h air separation unit at Wugang
Zhou Dun-wu, Huang Zheng-ming Corp. , Baiyushan, Qingshan District, Wuhan , Httbei, P. R. China). Analysis and treatment of the fault with chilling water distributor of air cooling tower in a 60000m^3/h air separation unit at Wugang[J]. Cryogenic Technology, 2007, 0(4): 46-48
Authors:Zhou Dun-wu   Huang Zheng-ming Corp.    Baiyushan   Qingshan District   Wuhan    Httbei   P. R. China)
Affiliation:Oxygen Co. , Ltd. of Wuhan Iron and Steel ( Group
Abstract:The fault with chilling water distributor of air cooling tower in a 60000m^3/h air separation unit is introduced, accompanied by the procedure of location detecting. Based on the cause analysis of the fault occurrence, the corresponding precautions are presented.
Keywords:Large scale air separation unit   Air precooling system   Water distributor
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号