首页 | 本学科首页   官方微博 | 高级检索  
     

BA-103裂解炉性能测试
引用本文:徐生荣. BA-103裂解炉性能测试[J]. 南京师范大学学报, 2004, 4(4): 25-27
作者姓名:徐生荣
作者单位:南京师范大学动力工程学院 江苏南京210042
摘    要:通过对BA-103裂解炉进行的性能测试,了解该炉改造后的效果.测试结果说明,裂解炉炉内烟气温度、炉墙内外壁温度、炉管管壁温度分布符合设计要求.散热损失较小,说明炉墙保温层设计、安装合理;排烟热损失较大是因为过剩空气系数偏大和排烟温度较高.该炉的实测热效率超过设计要求.裂解炉的改造达到了节能降耗、增加产出的预期目的.

关 键 词:裂解炉 温度测量 烟气分析 热平衡
文章编号:1672-1292-(2004)04-0025-03
修稿时间:2004-03-15

Performance Tests and Analysis of BA-103 Cracking Still
XU Shengrong. Performance Tests and Analysis of BA-103 Cracking Still[J]. Journal of Nanjing Nor Univ: Eng and Technol, 2004, 4(4): 25-27
Authors:XU Shengrong
Abstract:According to the performance tests in BA-103 cracking still, the effect of the transformed stove has been gained. The tests have shown that in the cracking still, the temperature distribution in the gas and the wall setting as well as the cracking tubes can meet the design requirements. The loss of heat dissipating is smaller, indicating the insulating layer design of the stove wall and the installation have been properly made; the thermal loss of the exhaust gas is more because the excess air coefficient is big and the gas temperature is higher. The thermal efficiency of this stove satisfies the design requirement, and the transformation of the cracking still has achieved the purpose in saving energy, reducing consumption and increasing the output.
Keywords:cracking still   temperature measurement   gas analysis   thermal equilibrium
本文献已被 CNKI 维普 万方数据 等数据库收录!