首页 | 本学科首页   官方微博 | 高级检索  
     


Treatment of oilfield wastewater by Fenton's process.
Authors:Y X Gao  M Yang  Y Zhang  J Y Hu
Affiliation:Department of Urban and Environmental Sciences, Peking University, Beijing, 100871, China. longwisher@yahoo.com.cn
Abstract:A combination of coagulation and Fenton's process was used for the removal of total oxygen carbon (TOC) from oilfield wastewater. Compared with aluminium sulfate, ferric coagulant had better TOC removal efficiency at the same mass dosage. In Fenton's process, the effect of H2O2 and Fe2+ dose on the removal of TOC was studied. The optimum conditions required for TOC removal were an Fe3+ concentration of 40-50 mg/L, an H2O2 dose of 50 mmol/L and an Fe2+ concentration of 1.0 mmol/L. GC-MS chromatographic analysis indicated that most of the alkyl hydrocarbons of carbon numbers < 21 were removed in the first minute of Fenton's process mainly through adsorption. Alkyl hydrocarbons and phenols were oxidized almost completely following 120 min of treatment. The pathway of newly formed intermediates in Fenton's process was proposed on the basis of the GC/MS chromatogram.