首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of real-time ice concentration inside pipeline by the refractive index method
Authors:Lee  Donggyu  Chung  Dong-Yeol  Kang   Chaedong  Peck   Jong-Hyeon
Affiliation:1.Graduate School, Chonbuk National University, Jeonju-si, 561-756, Korea
;2.Thermal & Fluid Sytem R&BD Group, Korea Institute of Industrial Technology (KITECH), Cheonan-si, 331-822, Korea
;3.Dept. of Mechanical Engineering and Geothermal Energy Technology Research Center, Chonbuk National University, Jeonju-si, 561-756, Korea
;
Abstract:

Ice fraction (or ice concentration, IC) of the ice slurry flowing through the pipe is very difficult to measure directly and in real time in ice slurry type system in thermal energy storage system. Measuring IC is very important to calculate the capacity of cold energy supplied through a pipeline. Ice fraction measurement methods have been reported as using density, electric resistance, electric conductivity, freezing point etc. However, the conventional methods are not perfect in terms of the resolution and accuracy. In this study, a new method is suggested to measure the IC of the ice slurry flowing through a pipe, which is used for a refractometer with low electrical noise and high resolution. To measure IC of the flowing ice slurry aqueous solution in pipe, it was installed in the test section to mass flow meter, refractometer, cyclone, and RTD (Resistance temperature detector) sensor. From the experiment, IC measurement method by using refractive index showed better result than others for the ice slurry in pipeline flowing or slurry tank.

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏