连续退火炉的改造及工艺调试 |
| |
引用本文: | 任凤章,董进图,魏震,王岗栓,袁新生.连续退火炉的改造及工艺调试[J].轴承,2000(4):17-19. |
| |
作者姓名: | 任凤章 董进图 魏震 王岗栓 袁新生 |
| |
作者单位: | 1. 西安交通大学,陕西西安,710049 2. 洛阳金冕实业总公司,河南洛阳,471041 3. 洛阳轴承研究所,河南洛阳,471039 |
| |
摘 要: | 分析了原退火炉设计及制造的不足 ,在 4区中部和 5区前端各增设一台均温风扇 ,去掉 6区炉顶的保温层 ,相应改变等温退火工艺。生产实践表明 ,退火质量提高 ,能耗降低。附图 2幅 ,表 4个。
|
关 键 词: | 轴承 连续退火炉 工艺调试 技术改造 |
修稿时间: | 1998-08-19 |
Transformation and Technology Testing of Continuous Annealing Fumace |
| |
Abstract: | The insufficient aspects in design and manufacture of the origin annealing furnace are analyzed,one fan for uniforming temperature is respectively added at the middle part of 4 region and the front part of 5 region,the heat preservation layer on the furnace top of 6 region is removed and the isothermal annealing technology is improved.The actual production shows that the annealing quality is increased and the energy consumption is decreased. |
| |
Keywords: | |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
|