首页 | 本学科首页   官方微博 | 高级检索  
     

W型辐射管损坏原因分析及维护要点
引用本文:白世宏,李芳,柳庆坡. W型辐射管损坏原因分析及维护要点[J]. 工业炉, 2010, 32(2): 48-50
作者姓名:白世宏  李芳  柳庆坡
作者单位:鞍钢股份有限公司,冷轧厂,辽宁,鞍山,114021;安阳职业技术学院,机电工程系,河南,安阳,455004
摘    要:对鞍钢冷轧厂镀锌线W型辐射管和连续退火W型辐射管损坏现象进行分析,找出了W型辐射管损坏的原因,并从几个方面给出了相应的维护和改进措施。

关 键 词:W型辐射管  连续退火炉  改进

Breakage Cause Analysis and Maintenance Point of Type W Radiant Tube
BAI Shi-hong,LI Fang,LIU Qing-po. Breakage Cause Analysis and Maintenance Point of Type W Radiant Tube[J]. Industrial Furnace, 2010, 32(2): 48-50
Authors:BAI Shi-hong  LI Fang  LIU Qing-po
Affiliation:1.Cold Rolling Plant,Angang Steel Co.,Ltd,Anshan 114021,China;2.Department of Machine & Electrical Engineering,Anyang Vocational and Technical College,Anyang 455004,China)
Abstract:The breakage phenomenon of the type W radiant tube in the galvanizing line and the continuous annealing line in Angang Cold Rolling Plant is analyzed,and the causes are founded out.Some relevant measures about maintenance and improvement in certain respects are given.
Keywords:type W radiant tube  continuous annealing furnace  improvement