首页 | 本学科首页   官方微博 | 高级检索  
     

转炉煤气轴流风机振动故障分析与处理
引用本文:杨朝刚,杨国军,金洪水,江洪兵.转炉煤气轴流风机振动故障分析与处理[J].风机技术,2014(1):87-92.
作者姓名:杨朝刚  杨国军  金洪水  江洪兵
作者单位:浙江义乌星耀风机有限公司,浙江义乌322000
摘    要:转炉煤气轴流风机在出厂试验台发生振动问题,采用了若干振动检测和分析方法,诊断结果为振动是由多种因素包括定子结构共振、转子临界转速频率边带过宽、叶轮不平衡三者共同作用而导致的振动问题,提出了故障处理原则和方法,从根本上解决了该风机的振动问题。

关 键 词:转炉煤气  轴流风机  结构共振  频率边带  叶轮不平衡  模态试验  故障分析

Vibration Analysis and Diagnosis Disposal for Axial ID Fan
Yang Chaogang,Yang Guojun,Hongshui,Jiang Hongbing.Vibration Analysis and Diagnosis Disposal for Axial ID Fan[J].Compressor Blower & Fan Technology,2014(1):87-92.
Authors:Yang Chaogang  Yang Guojun  Hongshui  Jiang Hongbing
Affiliation:(Zhejiang Yiwu Xingyao Fan Co.,Ltd.)
Abstract:Aiming at vibration of axial ID fan occurred on the fan test bench, many methods of vibration testing & analysis were used. The reasons including stator structure resonance, big side-band of frequency for stator critical speed, and impeller unbalance were the basic causes. By odopting improvement actions, the vibration fault was solved successfully.
Keywords:converter gas  axial ID fan  structure resonance  frequency side-band  impeller unbalance  modal test  fault diagnosis