首页 | 本学科首页   官方微博 | 高级检索  
     


Heat transfer and friction factor correlations of solar air heater ducts artificially roughened with discrete V-down ribs
Authors:Sukhmeet Singh  Subhash ChanderJ.S. Saini
Affiliation:a Department of Mechanical Engineering, Dr. B.R. Ambedkar National Institute of Technology, Jalandhar, India
b Department of Mechanical and Industrial Engineering, Indian Institute of Technology, Roorkee, India
Abstract:The heat and fluid flow characteristics of rectangular duct having its one broad wall heated and roughened with periodic ‘discrete V-down rib’ are experimentally investigated. Reynolds number (Re) has been varied from 3000-15000 with relative gap width (g/e) and relative gap position (d/w) range of 0.5-2.0 and 0.20-0.80 respectively. The respective variation in relative roughness pitch (P/e), angle of attack (α) and relative roughness height (e/Dh) have been 4-12, 30°-75° and 0.015-0.043. The effect of roughness parameters on Nusselt number (Nu) and friction factor (f) has been determined and the results obtained were compared with those of smooth duct. The maximum increase in Nu and f over that of smooth duct was 3.04 and 3.11 folds respectively. The rib parameters corresponding to maximum increase in Nu and f were d/w = 0.65, g/e = 1.0, P/e = 8.0, α = 60° and e/Dh = 0.043. Correlations for the Nu and f in terms of Re and rib parameters have been developed.
Keywords:Rib roughness parameters   Relative roughness pitch   Relative gap position   Angle of attack   Relative gap width
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号