首页 | 本学科首页   官方微博 | 高级检索  
     

焦作电厂1号炉再热汽温低的原因及防治对策
引用本文:乔永生,薛长海,李永宁. 焦作电厂1号炉再热汽温低的原因及防治对策[J]. 电力科学与工程, 2001, 0(4): 17-19
作者姓名:乔永生  薛长海  李永宁
作者单位:焦作电厂,河南,焦作,454001
摘    要:焦作电厂 1号炉在低负荷运行时 ,出现了再热汽温低、偏差大的现象。详细分析了出现这种情况的原因 ,并在运行控制和设备改进方面有针对性地提出了防治对策。

关 键 词:再热汽温  低负荷  偏低
文章编号:1006-6705(2001)04-0017-03
修稿时间:2001-05-28

Cause Analysis and Countermeasure for Low Reheated Steam Temperature of No. 1 Boiler in Jiaozuo Power Plant
QIAO Yong-sheng,XUE Chang-hai,LI Yong-ning. Cause Analysis and Countermeasure for Low Reheated Steam Temperature of No. 1 Boiler in Jiaozuo Power Plant[J]. Power Science and Engineering, 2001, 0(4): 17-19
Authors:QIAO Yong-sheng  XUE Chang-hai  LI Yong-ning
Abstract:The reheated steam temperature is far below the rated value and large difference exists between the two sides in No.1 boiler of Jiaozuo Power Plant during low load operation. The cause is analyzed in detail and improvement schemes are proposed.
Keywords:reheated stem temperature  low load  rather low