Detection of buckling in steel pipeline and column by the distributed Brillouin sensor
Authors:Fabien Ravet   Lufan Zou   Xiaoyi Bao   Liang Chen   Rong Feng Huang  Heng Aik Khoo
Affiliation:aFiber Optic Group, University of Ottawa, 150 Louis-Pasteur, Ottawa, ON K1N 6N5, Canada;bDepartment of Civil and Environmental Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, ON K1S 5B6, Canada
Abstract:We conducted a strain characterization experiment to monitor steel pipe and column buckling for the first time using a distributed Brillouin sensor system. Two specimens (steel pipe and column) were prepared by locally thinning the inner wall to initiate buckling. An axial load was applied to the specimens and increased while compressive strain was measured by both Brillouin sensor and strain gauges. With the Brillouin sensor, we observed compression on the whole specimens while elongation was detected in the neighborhood of the thinned wall at onset of the buckling. Both tension and compression are measured simultaneously from the same spectrum. This capability to extract both informations at the same time makes the Brillouin sensor a unique tool for structural health monitoring. The buckling was identified and localized thanks to this original approach.
Keywords:Distributed Brillouin sensor   Strain sensor   Structural health monitoring