首页 | 本学科首页   官方微博 | 高级检索  
     


Mitigating check valve slamming and subsequentwater hammer events for PPFS using MOC
Authors:TIAN Wenxi  SU Guanghui  WANG Gaopeng  QIU Suizheng  XIAO Zejun
Affiliation:Key Laboratory of Multiphase Flow in Power Engineering, Department of Nuclear Science and Technology,Xi'an Jiaotong University, Xi'an 710049, China;2.National Key Laboratory of Bubble Physics & Natural Circulation, Nuclear Power Institute of China, Chengdu 610041, China)
Abstract:The method of characteristic (MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System (PPFS) during the alternate startup process. The motion of check valve disc was simulated using inertial valve model. Transient parameters including the pressure oscillation, local flow velocity and slamming of the check valve disc etc. have been obtained. The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps. The induced maximum pressure vibration amplitude is up to 5.0 MPa. The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer. It has been numerically approved to be an effective approach.
Keywords:Water hammer  Check valve slamming  Method of characteristic  Inertia-type valve model
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号