摘    要:Considering the fact that the temperature distribution in furnace of a tangential fired pulverized coal boiler is difficult to be measured and monitored, two-stage numerical simulation method was put forward. First, multifield coupling simulation in typical work conditions was carried out off-line with the software CFX-4.3, and then the expression of temperature profile varying with operating parameter was obtained. According to real-time operating parameters, the temperature at arbitrary point of the furnace can be calculated by using this expression. Thus the temperature profile can be shown on-line and monitoring for combustion state in the furnace is realized. The simulation model was checked by the parameters measured in an operating boiler, DO130-9. 8/540. The maximum of relative error is less than 12% and the absolute error is less than 120℃, which shows that the proposed two-stage simulation method is reliable and able to satisfy the requirement of industrial application.

关 键 词:粉煤锅炉 燃烧监测 温度分布 数值模拟
收稿时间:2004-03-10
修稿时间:2004-06-11

Two-stage numerical simulation for temperature profile in furnace of tangentially fired pulverized coal boiler
Zhou Nai-jun , Xu Qiong-hui and Zhou Ping. Two-stage numerical simulation for temperature profile in furnace of tangentially fired pulverized coal boiler[J]. Journal of Central South University of Technology, 2005, 12(1): 97-101. DOI: 10.1007/s11771-005-0212-9
Authors:Zhou Nai-jun    Xu Qiong-hui   Zhou Ping
Affiliation:(1) School of Energy and Power Engineering, Central South University, 410083 Changsha, China
Abstract:Considering the fact that the temperature distribution in furnace of a tangential fired pulverized coal boiler is difficult to be measured and monitored, two-stage numerical simulation method was put forward. First, multi-field coupling simulation in typical work conditions was carried out off-line with the software CFX-4.3, and then the expression of temperature profile varying with operating parameter was obtained. According to real-time operating parameters, the temperature at arbitrary point of the furnace can be calculated by using this expression. Thus the temperature profile can be shown on-line and monitoring for combustion state in the furnace is realized. The simul-ation model was checked by the parameters measured in an operating boiler, DG130-9.8/540. The maximum of relative error is less than 12% and the absolute error is less than 120 ℃, which shows that the proposed two-stage simulation method is reliable and able to satisfy the requirement of industrial application.
Keywords:pulverized coal boiler  combustion monitoring  temperature distribution  numerical simulation