摘    要:从物料变化、仪表、设备等方面分析解吸水解系统在投产期间存在的一系列问题,针对水解工艺冷凝液电导率超标的问题制定了相应对策,并加以解决,实现了废水有效回收,达到了节能减排的目的。

关 键 词:水解电导  物料浓度  工艺冷凝液  设备泄漏

CAUSES OF PROCESS CONDENSATE ELECTRIC CONDUCTIVITY SURPLUS STANDARD IN UREA PLANT AND SOLUTIONS THEREOF
Chen Tiefeng,Yin Hongdong.CAUSES OF PROCESS CONDENSATE ELECTRIC CONDUCTIVITY SURPLUS STANDARD IN UREA PLANT AND SOLUTIONS THEREOF[J].Large Scale Nitrogenous Fertilizer Industry,2014(2):65-67.
Authors:Chen Tiefeng  Yin Hongdong
Affiliation:( Chongqing Jianfeng Chemical Industry Co. ,Ltd., Chongqing 408601 )
Abstract:Problems being existed in hydrolyzing system during commissioning were studied from as- pects of feedstock change, instrumentation and equipment. Regarding the problem of process condensate elec- tric conductivity beyond standard, corresponding measures were established to achieve effective recovery of waste water and energy saving and reduction of discharges.
Keywords:hydrolysis electric conductivity  feedstock concentration  process condensate  leakage in e-quipment