首页 | 本学科首页   官方微博 | 高级检索  
     

环境一号卫星CCD相机水体信息采集特性分析
引用本文:黄妙芬,牛生丽,孙中平,吴传庆,赵祖龙,化成君.环境一号卫星CCD相机水体信息采集特性分析[J].遥感信息,2010,0(4):68-75.
作者姓名:黄妙芬  牛生丽  孙中平  吴传庆  赵祖龙  化成君
作者单位:1. 大连海洋大学,大连,116023
2. 国家卫星海洋应用中心,北京,100081
3. 环境保护部卫星环境应用中心,北京,100029
基金项目:十一五"科技支撑项目,国家自然科学基金 
摘    要:利用覆盖我国4大海区共88景图像数据,针对4波段CCD相机(HJ-1A/CCD1、HJ-1A/CCD2、HJ-1B/CCD1、HJ-1B/CCD2)在水体中的信息采集特性进行分析。结果表明:(1)HJ-1A和B星虽不是水色卫星,但其CCD相机在水体中依然有一定的信息,可作为水色遥感器服务于水环境;(2)HJ-1B/CCD1在南海海域水体信息采集过程存在明显的太阳耀斑现象,因而在水色信息提取时太阳耀斑是一个不可忽略的因子;(3)无论是在一类水体还是在二类水体,各遥感器的近红外波段皆存在水体信息采集为零的现象,其中HJ1B-CCD2尤为明显。利用近10景涵盖了HJ-1A/CCD1、HJ-1A/CCD2、HJ-1B/CCD1、HJ-1B/CCD2数据,以及同时过境的EOS/MODIS,采用基于遥感器入瞳处总辐亮度的交叉定标方法进行交叉辐射定标,获取适用于水体目标的交叉辐射定标参数。最后根据瑞利散射和气溶胶散射的计算值,以及获取的交叉定标系数,反推出HJ1B-CCD2可能接受到的灰度值。

关 键 词:环境一号卫星(HJ-1)  水体信息  区域灰度值  近红外波段  交叉定标系数
收稿时间:2009-09-23
修稿时间:2009-10-25

Analysis on Characteristics of the Water Information Collected by "HJ-1" Satellite Multispectral CCD Sensors
HUANG Miao-fen,NIU Sheng-li,SUN Zhong-ping,WU Chuan-qing,ZHAO Zu-long,HUA cheng-jun.Analysis on Characteristics of the Water Information Collected by "HJ-1" Satellite Multispectral CCD Sensors[J].Remote Sensing Information,2010,0(4):68-75.
Authors:HUANG Miao-fen  NIU Sheng-li  SUN Zhong-ping  WU Chuan-qing  ZHAO Zu-long  HUA cheng-jun
Affiliation:1 Dalian Ocean University,Dalian 116023;2 National Satellite Ocean Application Service,Beijing 100081;3 Satellite Environment Center,Ministry of Environmental Protection(SEC,MEP),Beijing 100029)
Abstract:The home-made satellites 'HJ-1A' and 'HJ-1B' were successfully launched in September 2008.Their role is to serve the country's disaster and environmental monitoring.The main sensors on the satellites are 4-band CCD cameras with a wide coverage,hyperspectral imager(HSI) and infrared cameras(IRS).In this paper,the water information characteristics of the 4-band CCD cameras(HJ-1A/CCD1,HJ-1A/CCD2,HJ-1B/CCD1,HJ-1B/CCD2) were analyzed.The results showed that(1) although HJ-1A and B are not water color satellite,but each sensor still has some information about the water,so it can be used as water color remote sensors for water environment study;(2) for HJ-1B/CCD1 during water information collection in the South China Sea exists an obvious phenomenon of solar flares,so in the extraction of water color information that should not be ignored;(3) whether in case 1 or in case 2,this situation happens,the water body information of near-infrared bands of each sensor is zero,especially of HJ1B-CCD2.The four visible and near-infrared spectral bands of HJ-1/CCD1,HJ-1A/CCD2,HJ-1B/CCD1 and HJ-1B/CCD2 were calibrated respectively using cross-calibration methods based on the EOS/MODIS.The latter has the high radiation precision,and simultaneously passed through the South China Sea.The Radiometric Calibration coefficients of water-body targets of "HJ-1" satellite multispectral CCD sensors were obtained and validated.Finally,according to the calculation value of rayleigh scattering and aerosol scattering,HJ1B-CCD2 should be able to receive the gray value;this provides a reference to the sensor data application.
Keywords:environmrnt-1 satellite(HJ-1)  water body information  regional gray value  near-infrared bands  cross-calibration coefficients
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《遥感信息》浏览原始摘要信息
点击此处可从《遥感信息》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号