摘    要:针对颜料企业生产废水pH波动大,有机污染物成分复杂与可生化性差的问题,采用Fenton法对颜料废水进行了预处理实验研究.通过研究在不同实验条件下,Fenton试剂预处理该类废水的COD去除率及处理成本,验证了Fenton法处理颜料企业生产废水的可行性并得到Fenton法预处理此类废水的最优实验条件.实验结果表明,Fenton试剂处理该废水的COD去除率最高可达81%;在最优实验条件下,COD去除率为52%,处理成本为4.3元/t;Fenton法处理颜料企业生产废水的影响因素依次为H2O2∶Fe2+(mol∶mol)H2O2∶COD(g∶g)出水pH.

关 键 词:Fenton试剂  颜料废水  有机废水  反应温度  反应时间  絮凝沉降  正交试验  水处理  

Pretreatment of wastewater in pigment factory with Fenton method
LIANG Ji-yan;CUI Chun-ling;CUI Li;WANG Xin;ZOU Cheng-long.Pretreatment of wastewater in pigment factory with Fenton method[J].Journal of Shenyang University of Technology,2014,36(4):476-480.
Authors:LIANG Ji-yan;CUI Chun-ling;CUI Li;WANG Xin;ZOU Cheng-long
Affiliation:School of Science, Shenyang University of Technology, Shenyang 110870, China
Abstract:In order to solve the problems that the pH fluctuation of wastewater in a pigment factory is big, the composition of organic pollutants is complicated and the biodegradability is poor, the experimental study on the pretreatment of wastewater in the pigment factory was performed with the Fenton method. Through the investigation on both removal rate of COD and processing cost under different experimental conditions when the wastewater was pretreated with the Fenton reagent, the feasibility for the pretreatment of wastewater with the Fenton method in the pigment factory was verified. In addition, the optimum experimental conditions for the pretreatment of wastewater with the Fenton method were obtained. The experimental results show that the maximum removal rate of COD after the pretreatment of wastewater with the Fenton method can be over 81%. Under the optimal experimental conditions, the removal rate of COD is 52%, and the processing cost is 4.3 yuan per ton. The influencing factors for the pretreatment of wastewater in the pigment factory with the Fenton method are successively H2O2∶Fe2+(mol∶mol)&; gt; H2O2∶COD(g∶g)&; gt; effluent pH.
Keywords:Fenton reagent  pigment wastewater  organic wastewater  reaction temperature  reaction time  flocculating sedimentation  orthogonal test  water treatment  
本文献已被 CNKI 等数据库收录!
点击此处可从《沈阳工业大学学报》浏览原始摘要信息
点击此处可从《沈阳工业大学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号