摘    要:介绍了设备的工况、材料和制造工艺.分析了干燥再沸器、卧式再沸器管子-管板接头的失效 原因。对换热管管端外表面进行严格清理并采取液压胀管工艺,有效保证了换热器管子-管板接头的 制造质量。

关 键 词:管子-管板接头  失效  液压胀管
文章编号:1006-7906(2003)06-0028-03
修稿时间:2003年6月30日

Influence of joining method on reliability of tube-tubesheet joint of heat exchanger
PEI Feng.Influence of joining method on reliability of tube-tubesheet joint of heat exchanger[J].Journal of Chemical Industry & Engineering,2003,24(6):28-30.
Authors:PEI Feng
Abstract:The working condition, material and fabrication process of the unit is introduced. The factors of the failure on tube-tubesheet joint of heat exchanger are analyzed. Entirely cleaning of outer surface of tube end and adopting of hydraulic expanding are effective to assure the quality of the tube-tubesheet joint of heat exchanger.
Keywords:Tube-tubesheet joint  Failure  Hydraulic expanding