首页 | 本学科首页   官方微博 | 高级检索  
     

铅铋合金中Bi/Bi_2O_3型氧传感器准确性及稳定性测试研究
引用本文:王艳青,黄群英,武欣,吴斌,张敏,高胜. 铅铋合金中Bi/Bi_2O_3型氧传感器准确性及稳定性测试研究[J]. 原子能科学技术, 2015, 49(3): 572-576. DOI: 10.7538/yzk.2015.49.03.0572
作者姓名:王艳青  黄群英  武欣  吴斌  张敏  高胜
作者单位:1.中国科学技术大学,安徽 合肥230027;2.中国科学院 核能安全技术研究所,中国科学院 中子输运理论与辐射安全重点实验室,安徽 合肥230031
基金项目:中国科学院战略性先导科技专项资助项目(XDA03040000);中国科学院知识创新工程重要方向项目资助(KJCX2-YW-N37);国家自然科学基金重点支持项目资助(91026004)
摘    要:液态铅铋合金(LBE)中溶解氧浓度的精确测量是实现LBE中氧浓度控制的前提。本文用一自主研制的Bi/Bi2O3型氧传感器来测量LBE氧浓度,在静态氧饱和的LBE中分别进行了准确性及稳定性测试。准确性测试结果表明,在340~480℃范围内氧传感器电动势实验曲线随温度的变化与理论曲线一致,电动势绝对误差最大为-2.6 mV;稳定性测试结果表明,在450℃、50h内电动势绝对误差为-1.4mV,波动为4mV。

关 键 词:铅铋合金   氧浓度   氧传感器   电动势

Accuracy and Stability Test Study of Bi/Bi2O3 Oxygen Sensor in Lead-bismuth Eutectic
WANG Yan-qing;HUANG Qun-ying;WU Xin;WU Bin;ZHANG Min;GAO Sheng. Accuracy and Stability Test Study of Bi/Bi2O3 Oxygen Sensor in Lead-bismuth Eutectic[J]. Atomic Energy Science and Technology, 2015, 49(3): 572-576. DOI: 10.7538/yzk.2015.49.03.0572
Authors:WANG Yan-qing  HUANG Qun-ying  WU Xin  WU Bin  ZHANG Min  GAO Sheng
Affiliation:1.University of Science and Technology of China, Hefei 230027, China;2.Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei 230031, China
Abstract:Accurate measurement of the concentration of dissolved oxygen in liquid lead-bismuth eutectic (LBE) is the premise to achieve oxygen control. A self-developed Bi/Bi2O3 oxygen sensor was used to measure oxygen concentration in LBE. The accuracy and stability tests were carried out in stagnant liquid LBE in the condition of oxygen saturation. The accuracy test results show that the change of experimental electromotive force with temperature is consistent with the theoretical curve in the temperature ranging from 340 ℃ to 480 ℃. The maximum absolute error of electromotive force is -2.6 mV. The stability test results show that the absolute error of electromotive force is -1.4 mV within 50 hours at the temperature of 450 ℃ and the fluctuation in this test is 4 mV.
Keywords:lead-bismuth eutectic  oxygen concentration  oxygen sensor  electromotive force
本文献已被 CNKI 等数据库收录!
点击此处可从《原子能科学技术》浏览原始摘要信息
点击此处可从《原子能科学技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号