摘    要:隆达发电有限公司2号汽轮发电机组运行中,在没有进行任何操作情况下,5号轴承处轴振动突增,经分析认为振动突增原因为发电机转子匝间短路。经进行配重平衡,故障消除。

关 键 词:135MW  汽轮发电机组  振动  匝间短路  配重
文章编号:1002-3364(2006)10-0052-02
收稿时间:2006-05-08
修稿时间:2006年5月8日

DIAGNOSIS AND TREATMENT OF SUDDEMLY APPEARED VIBRATION ON TURBOGENERATOR SET
DAI Guo-chao,ZHANG Quan-ping,CHEN Jian-jun.DIAGNOSIS AND TREATMENT OF SUDDEMLY APPEARED VIBRATION ON TURBOGENERATOR SET[J].Thermal Power Generation,2006,35(10):52-53.
Authors:DAI Guo-chao  ZHANG Quan-ping  CHEN Jian-jun
Abstract:On turbo-generator no.5 in Longda Power-Generation Co Ltd,shaft vibration at bearing no.5 has suddenly increased in operation under condition without carrying out any manipulation.Through analysis,it is believed that the sudden increase of vibration is caused by interturn short circuit in the rotor of generator.Through carrying out counter weight balance,the said accident has been eliminated.