摘    要:建在地下钢筋混凝土水池之上的框架结构的嵌固端位置不易确定,相关规范中也没有明确描述。本文结合具体工程实例,利用结构设计软件PKPM对该问题进行了分析探讨,结果表明,可将水池顶部作为框架结构的嵌固端。该分析的结果具有普适性,可供类似的工程作为参考。

关 键 词:水池  框架  嵌固端  侧向刚度比

Analysis of the Location for the End Restraint of the Frame Structure which Built on Top of the Underground Reinforced Concrete Water Tank
Abstract:The location for the end restraint of the frame structure which built on top of the underground reinforced concrete water tank was unable to be clearly identified,in which the codes and standards was also not clearly described.The problem was investigated and analysed with real practical engineering projects and structure design software PKPM in this article.The outcome indicated that the top of the water tank could be used as the end restraint for the frame structure.The analysed results are adaptable and can be referenced for similar engineering projects.
Keywords:Water Tank  Frame Structure  End Restraint  Lateral Stiffness Ratio