首页 | 本学科首页   官方微博 | 高级检索  
     

国产超临界600MW机组发电机定冷水线圈温差大的分析和处理
引用本文:陈志秋.国产超临界600MW机组发电机定冷水线圈温差大的分析和处理[J].广东电力,2012(8):117-121.
作者姓名:陈志秋
作者单位:广东珠海金湾发电有限公司,广东珠海,519000
摘    要:根据某电厂超临界发电机组定冷水线圈温差异常的现象,分析了定子线圈堵塞物形成原因,并用碱洗加酸洗加漂洗钝化的复合清洗工艺进行有效的处理。经清洗后,成功清除定子线圈堵塞物,解决了定子线圈温差异常的问题,保证了发电机安全运行。

关 键 词:定子线圈  温度异常  氧化物  化学清洗

Analysis and Treatment on Big Temperature Difference of Stator Cooling Water Coil of Homemade Supercritical 600 MW Units
CHEN Zhiqiu.Analysis and Treatment on Big Temperature Difference of Stator Cooling Water Coil of Homemade Supercritical 600 MW Units[J].Guangdong Electric Power,2012(8):117-121.
Authors:CHEN Zhiqiu
Affiliation:CHEN Zhiqiu (Guangdong Zhuhai Jinwan Power Generation Co. , Ltd. , Zhuhai, Guangdong 519000, China)
Abstract:In accordance to abnormal temperature of stator cooling water coil of supercritical generating units in a power plant, the paper analyzes causes for stemming of stator coil and integrated cleaning process of alkaline washing and rinsing passivation for treatment. After being washed, the stemming is removed, temperature difference of stator coil is handled and hence safe operation of generator is guaranteed.
Keywords:stator coil  temperature abnormity  oxide  chemical cleaning