摘    要:300MW机组强制循环锅炉用炉水循环泵控制工质在汽水系统中循环,在不同的工质状态下.炉水循环泵启动对锅炉汽包水位有不同的影响,通过分析其原因,提出合理的炉水泵运行方法,以避免锅炉主燃料跳闸(MFT)事故的发生。

关 键 词:汽包  炉水循环泵  水位
文章编号:1004-3950(2006)04-0067-03
收稿时间:2006-02-22
修稿时间:2006-02-22

Varations of drum level with starting up of boiler circulating pump in the forced circulation boiler
XU Xiao-qiong , WU Bi-jun, PAN Guo-qing , et al. Varations of drum level with starting up of boiler circulating pump in the forced circulation boiler[J]. Energy Engineering, 2006, 0(4): 67-69
Authors:XU Xiao-qiong    WU Bi-jun   PAN Guo-qing    et al
Abstract:Boiler circulating pumps are used to control boiler water circulation in the 300 MW units. Drum level varies while starting up the boiler circulating pumps in different water temperature and pressure. This cause was studied in this paper and reasonable operation method was proposed to avoid boiler MFT.