Consideration of multi‐coil type magnetization system for magnetic particle testing of omnidirectional crack in all surfaces of 3D shape test object
Authors:Katsuhiro Fukuoka  Masaki Kobayashi  Tomohiro Ozaki  Yoshiro Oikawa
Affiliation:1. The University of Shiga Prefecture, Hikone, Japan;2. Denshijiki Industries, Tokyo, Japan
Abstract:Mechanical parts, plants, and cross‐linkages inspected with magnetic‐particle testing (MT) are typically complex 3D shapes. In complex 3D shape portions, because a magnetizer often cannot be configured to inspection portions and the test object cannot be appropriately magnetized, there is a possibility of overlooking a crack in such an instance. Thus, MT system development that was successfully able to detect omnidirectional cracks in 3D shape portions was considered in this study's trials. Two multi‐coil type magnetizers were hence arranged face‐to‐face, and the magnetization of omnidirectional scenarios for all surfaces of 3D shape test object was evaluated.
Keywords:3D shape test object  magnetic‐particle testing  multi‐coil type magnetizer  omnidirectional magnetization  rotating magnetic field