首页 | 本学科首页   官方微博 | 高级检索  
     

高温蒸汽电解制氢系统温度敏感性分析
引用本文:刘明义,于波,徐景明,陈靖.高温蒸汽电解制氢系统温度敏感性分析[J].原子能科学技术,2009,43(10):881-885.
作者姓名:刘明义  于波  徐景明  陈靖
作者单位:清华大学 ;核能与新能源技术研究院,北京 ;100084
基金项目:教育部博士点专项新教师基金资助项目 
摘    要:通过电化学方法建立高温蒸汽电解制氢系统温度敏感性分析的数学模型,通过该模型对系统温度敏感性进行分析,并提出温度敏感系数的概念。定性的研究结果表明,在不同发电效率、电解效率以及热效率下,温度敏感系数均随着工作温度的增加而增大。这表明,系统总效率随着温度的升高而增大,且随着发电效率和热效率的增加,温度敏感系数也随之增大,但电解效率对温度敏感系数影响较小。定量的研究结果表明,工作温度为750~950℃的高温蒸汽电解制氢系统的温度敏感系数约为1.40,即系统工作温度分别为800和900℃时,由于温度升高而使系统总效率分别增加约10.5%和12%;相应的实际总制氢效率可分别高达55.8%和56.5%,约是常规碱性水电解制氢效率的两倍。

关 键 词:高温蒸汽电解    高温气冷堆    固体氧化物电解池    温度敏感系数    敏感性分析

Temperature Sensitivity Analysis of High Temperature Steam Electrolysis System for Hydrogen Production
LIU Ming-yi YU Bo XU Jing-ming CHEN Jing.Temperature Sensitivity Analysis of High Temperature Steam Electrolysis System for Hydrogen Production[J].Atomic Energy Science and Technology,2009,43(10):881-885.
Authors:LIU Ming-yi YU Bo XU Jing-ming CHEN Jing
Affiliation:Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China
Abstract:In this study, the temperature sensitive analysis model of the high temperature steam electrolysis (HTSE) system was established through electrochemical method. Temperature sensitivity of the HTSE system was analyzed using this model. The concept of temperature sensitive coefficient was put forward originally. Qualitative researches show the temperature sensitive coefficient increase with operation temperatures increasing under various electrical efficiency (ηel), electrolysis efficiency (ηes), and thermal efficiency (ηth), which indicate the overall system efficiency of the HTSE system increases with operation temperatures increasing. And the temperature sensitive coefficient increase with ηel and ηth increasing, while ηes has little effect on the temperature sensitive coefficient. Quantitative researches show the temperature sensitive coefficient is 1.4 with the operation temperatures in the range of 750-950 ℃, which indicates the overall system efficiency increases about 10.5% and 12%, when the operation temperatures of the HTSE system are 800 and 900 ℃, respectively. Then the overall system efficiency of the actual HTGR coupled with HTSE system is as high as 55.8% and 56.5%, respectively, which is about two times higher than that of the conventional alkaline water electrolysis.
Keywords:high temperature steam electrolysis  high-temperature gas-cooled reactor  solid oxide electrolysis cell  temperature sensitive coefficient  sensitivity analysis
本文献已被 万方数据 等数据库收录!
点击此处可从《原子能科学技术》浏览原始摘要信息
点击此处可从《原子能科学技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号