首页 | 本学科首页   官方微博 | 高级检索  
     

Commercial Application of the RAR Sulfur Recovery and Tail Gas Treating Process
引用本文:GuoHong ZhangSongping. Commercial Application of the RAR Sulfur Recovery and Tail Gas Treating Process[J]. 中国炼油与石油化工, 2003, 0(4): 1-9
作者姓名:GuoHong ZhangSongping
作者单位:RefineryofJinlingPetrochemicalCompany,Nanjing210033
摘    要:The 40kt/a sulfur recovery unit for tail gas treating applying the reduction-absorption-recycling (RAR) technology is aimed at regeneration of the rich amine solution and recovery of sulfur to operate in tandem with the 1.2Mt/a diesel hydrofining unit. The process unit calibration data have revealed that the recovery of total sulfur reaches 99.86%, which is 6.65 percentage points higher than that before application of the RAR technology. The SO2 content in vented tail gas is 0.27 t/d, which is much less than the latest emission standard prescribed by the State. The factors that can affect the unit operation have been analyzed and corresponding measures have been suggested including the necessity to improve the control over the reaction temperature in the tail gas hydrogenation unit.

关 键 词:尾气处理技术 硫回收技术 加氢精制工艺 石油化工行业 炼油工业 环境保护 大气污染

Commercial Application of the RAR Sulfur Recovery and Tail Gas Treating Process
Guo Hong,Zhang Songping. Commercial Application of the RAR Sulfur Recovery and Tail Gas Treating Process[J]. China Petroleum Processing and Petrochemical Technology, 2003, 0(4): 1-9
Authors:Guo Hong  Zhang Songping
Abstract:The 40kt/a sulfur recovery unit for tail gas treating applying the reduction-absorption-recycling (RAR) technology is aimed at regeneration of the rich amine solution and recovery of sulfur to operate in tandem with the 1.2Mt/a diesel hydrofining unit. The process unit calibration data have revealed that the recovery of total sulfur reaches 99.86%, which is 6.65 percentage points higher than that before application of the RAR technology. The SO2 content in vented tail gas is 0.27 t/d, which is much less than the latest emission standard prescribed by the State. The factors that can affect the unit operation have been analyzed and corresponding measures have been suggested including the necessity to improve the control over the reaction temperature in the tail gas hydrogenation unit.
Keywords:sulfur recovery unit  tail gas  commercial scale  Claus sulfur recovery
本文献已被 维普 万方数据 等数据库收录!