摘    要:为研究锈损对冷弯薄壁型钢短柱受压承载性能的影响,设计加工了6个轴压及6个绕强轴偏心受压短柱试件,首先通过拉伸试验,分析了材料力学性能与锈蚀程度间的关系,然后对试件进行承载力试验,分析其破坏模式、极限承载力及变形特征等特性,结果表明:锈损钢材的屈服、抗拉强度、弹性模量及伸长率均随锈蚀程度的增加呈线性下降趋势.锈损未使短柱...

关 键 词:锈损  冷弯薄壁型钢  承载力试验  受压构件  失稳模式
收稿时间:2020-06-14

EXPERIMENTAL INVESTIGATION ON COMPRESSIVE BEARING CAPACITY OF COLD-FORMED THIN-WALLED LIPPED CHANNEL SHORT COLUMNS WITH CORROSION
XU Ji-min,XING Kun-tao,GAO Xiang-yu,XU Shan-hua,GUO Xiao-hua,NIE Biao. EXPERIMENTAL INVESTIGATION ON COMPRESSIVE BEARING CAPACITY OF COLD-FORMED THIN-WALLED LIPPED CHANNEL SHORT COLUMNS WITH CORROSION[J]. Engineering Mechanics, 2021, 38(4): 191-199,210. DOI: 10.6052/j.issn.1000-4750.2020.06.0376
Authors:XU Ji-min  XING Kun-tao  GAO Xiang-yu  XU Shan-hua  GUO Xiao-hua  NIE Biao
Affiliation:1.Central Research Institute of Building and Construction Co. Ltd, MCC Group, Beijing 100088, China2.Beijing Key Lab of Earthquake Engineering and Structural Retrofit, Beijing University of Technology, Beijing 100124, China3.School of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
Abstract:To investigate the effect of corrosion on the compressive bearing capacity of cold-formed thin-walled steel short columns, six specimens under axial compression and six specimens under eccentric compression around strong axes were designed and processed. First, the relationship between the mechanical properties of materials and the degree of corrosion was analyzed through tensile tests. Then, the bearing capacity tests of specimens were carried out, and the failure modes and ultimate load-bearing capacity were analyzed. The results show that the yield, tensile strength, modulus of elasticity and the elongation of corroded steel decrease linearly with the increase of corrosion degree. The corrosion of steel does not change the final failure mode of the short column specimens, but with the increase of eccentricity, the local buckling of the web becomes a coupling failure mode dominated by distortion buckling. Under the same corrosion rate, the ultimate bearing capacity of axially compressed specimens degrades more obviously than that of eccentrically compressed specimens. The ABAQUS finite element software was used to simulate the specimens. The results show that the ABAQUS software can better predict the bearing capacity and buckling behavior of the specimens.
Keywords:corrosion  cold-formed thin-walled steel  bearing capacity test  compression member  buckling mode
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《工程力学》浏览原始摘要信息
点击此处可从《工程力学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号