首页 | 本学科首页   官方微博 | 高级检索  
     

高效蓄能互联热泵系统技术及应用
引用本文:周珏,罗凡,罗庚玉,陈建平,余承霖,周强.高效蓄能互联热泵系统技术及应用[J].电力需求侧管理,2017,19(6):25-28.
作者姓名:周珏  罗凡  罗庚玉  陈建平  余承霖  周强
作者单位:国网江苏电力需求侧管理指导中心有限公司,南京 210019,国网甘肃省电力公司,兰州 730050,法凯涞玛冷暖设备杭州有限公司,杭州 310007,法凯涞玛冷暖设备杭州有限公司,杭州 310007,法凯涞玛冷暖设备杭州有限公司,杭州 310007,国网江苏省节能服务公司,南京 210019
摘    要:在目前国家大气污染治理工作背景下,针对我国严寒地区及寒冷地区无法使用水地源热泵或地埋管热泵问题,以及使用空气源热泵存在能效比低、故障率高等问题,提出蓄能互联热泵系统清洁采暖方案,通过综合技术创新突破单一技术运用的客观限制,打造"不打井、不做地埋管"的水-水热泵系统,使得常规空气源热泵的使用边界扩大、稳定性增强、投资减少、故障率降低,并且能够在暖气片供暖系统改造中稳定提供60℃热水。以国网兰州建西变电站家属楼暖气片改造项目为例,进行了方案设计、设备选型和运行效果分析,验证了蓄联热泵系统的可靠性、经济性。

关 键 词:蓄能互联热泵系统  清洁供暖  节能减排  暖气片采暖改造
收稿时间:2017/8/4 0:00:00

Regulation method of voltage limits violation in distribution network withdistributed photovoltaic generation
ZHOU Jue,LUO Fan,LUO Geng.yu,CHEN Jian.ping,YU Cheng.lin and ZHOU Qiang.Regulation method of voltage limits violation in distribution network withdistributed photovoltaic generation[J].Power Demand Side Management,2017,19(6):25-28.
Authors:ZHOU Jue  LUO Fan  LUO Gengyu  CHEN Jianping  YU Chenglin and ZHOU Qiang
Affiliation:State Grid Jiangsu DSM Instruction Center Co., Ltd., Nanjing 210019, China,State Grid Gansu Electric Power Company, Lanzhou 730050, China,Hangzhou Airclima Warm and Cold Equipment Co., Ltd., Hangzhou 310007, China,Hangzhou Airclima Warm and Cold Equipment Co., Ltd., Hangzhou 310007, China,Hangzhou Airclima Warm and Cold Equipment Co., Ltd., Hangzhou 310007, China and State Grid Jiangsu Energy Conservation Service Company, Nanjing 210019, China
Abstract:Under the background of national air .pollutioncontrol, aiming at the cold area that can not use heat pump or watersource heat pump of buried pipe and low energy efficiency ratio andhigher failure rate of the use of air source heat pump,the energy stor.age heat pump system interconnection clean heating scheme is putforward, which break through the objective limit of single the use oftechnology through the comprehensive technical innovation, in orderto create" no well, no water heat pump system of buried tube".Theconventional air source heat pump utility boundary is expanded andthe stability is enhanced.The investmentis failure rate are reduced,which can provide stability in the transformation of the radiator heat.ing system in hot water 60 degrees.Taking the heating house recon.struction project of the family building in Lanzhou West substationas an example, the scheme design, equipment selection and opera.tion effect analysis are carried out, and the reliability and economyof the heat pump system are verified.
Keywords:energy storage interconnected heat pump sys  tem  clean heating  energy saving and emission reduction  radiatorheating transformation
本文献已被 CNKI 等数据库收录!
点击此处可从《电力需求侧管理》浏览原始摘要信息
点击此处可从《电力需求侧管理》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号