首页 | 本学科首页   官方微博 | 高级检索  
     


End-Winding Inductances of MVA Machines Through FEM Computations and IEC-Specified Measurements
Abstract: Correct finite-element method (FEM) computations of end-winding leakage inductances of MVA-range machines are discussed. This is shown through validations against total stator reactance measurements of 11 air-suspended stators and a reasonable agreement of FEM computations with the International Electrotechnical Commission 60034-4 standard. To achieve this goal, the need to have several 2-D and 3-D FEM models, including those representing the cooling ducts, is emphasized. Steps to utilize the validated stator FEM models for direct computation of end-winding leakage inductances are also listed. It is also shown that measurements of zero-sequence reactances cannot help the FEM validations and do not provide a reliable estimation of the leakage inductances.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号