基金项目:上海市教育委员会重点学科建设项目(J51303).
摘    要:介绍了中性点非直接接地配电系统的单相接地选线方法,并提出了利用零序电流比值法进行故障选线的方法,通过仿真分析证明了该方法的有效性.

关 键 词:中性点非直接接地系统  零序电流分布  故障选线  Matlab仿真
收稿时间:7/4/2011 12:00:00 AM

Ground Line of the Small Current System by the Rate Change of the Zero Sequence Current Calculating by Simulation
WANG Lei and XIE Jiang-yuan.Ground Line of the Small Current System by the Rate Change of the Zero Sequence Current Calculating by Simulation[J].Journal of Shanghai University of Electric Power,2012,28(5):427-430.
Authors:WANG Lei and XIE Jiang-yuan
Affiliation:1. Shanghai University of Electric Power, Shanghai 200090, China ; 2. Shenhua Guohua Windpower Co. Ltd, Dongtai 224200, China)
Abstract:The single-phase ground lining method of neutral system non-direct grounding is introduced and a method of fault circuit detection by adopting zero sequence current ratio method is put forward. The effectiveness of this method is proved through simulation.
Keywords:non-direct ground neutral system  zero sequence current distribution  fault line  Matlab simulation