摘    要:文章从输电线路实际运行环境和运行条件出发,对雷电造成输电线路故障的成因进行分析;阐明了雷害对输电线路的影响,以及采取输电线路防雷措施,对输电线路维持电力系统持续、可靠供电的重要性;从输电线路日常维护的角度对现采取的防雷措施进行分析,就提高输电线路防雷能力提出了相关建议。

关 键 词:高压线路  防雷研究  避雷器:输电线路

Lightning and Grounding Measures of Transmission Line and Its Maintenance
GANG Cun-jun,YE Yun-qing,YAN Zheng-gang. Lightning and Grounding Measures of Transmission Line and Its Maintenance[J]. Qinghai Electric Power, 2012, 0(3): 17-18
Authors:GANG Cun-jun  YE Yun-qing  YAN Zheng-gang
Affiliation:GANG Cun-jun,YE Yun-qing,YAN Zheng-gang
Abstract:The paper analyzes fault reason induced by lightning from actual operation environment and condition of transmission line,and discusses influence of lightning damage on the transmission line,as well as expounds the importance of adopting lightning measures to maintain continued and reliable power supply,besides the paper makes analysis on the present lightning measures from daily maintenance of the transmission line,and proposes corresponding suggestions on improving the lightning performance of the transmission line.
Keywords:high voltage transmission line  lightning research  lightning arrester  transmission line