A Comprehensive Study of Modified Wilson Plot Technique to Determine the Heat Transfer Coefficient during Condensation of Steam and R-134a over Single Horizontal Plain and Finned Tubes |
| |
Authors: | Ravi Kumar H K Varma K N Agrawal Bikash Mohanty |
| |
Affiliation: | W. M. Rohsenow Heat and Mass Transfer Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts |
| |
Abstract: | In the present investigation a comprehensive study of the modified Wilson plot technique has been made and a stepwise methodology has been evolved. This technique can be used to determine the condensing-side heat transfer coefficient during condensation of vapor over a horizontal tube. The necessary experimental data have been acquired by conducting experiments for the condensation of steam and R-134a over a plain tube and different finned tubes (CIFTs and SIFTs). The experimental heat transfer coefficient, based on the test-section wall temperature measurement (wall temperature was measured with thermocouples), ho, has been compared with that predicted by the modified Wilson plot technique, hmw. The modified Wilson plot technique underpredicted the condensing-side heat transfer coefficient for the condensation of steam in a range of 7.5-15%. The heat transfer coefficient for the condensation of R-134a is also underpredicted in a range of 13-25% by this technique. |
| |
Keywords: | |
|
|