首页 | 本学科首页   官方微博 | 高级检索  
     


Absolute Measurements of the Magnetic Field Generated by Different Coils in the Center of EGYPTOR Tokamak
Authors:H. Hegazy  F. Zacek
Affiliation:(1) EGYPTOR Project, Plasma Physics Department, NRC, Egyptian Atomic Energy Authority, 13759 Enshass, Egypt;(2) Institute of Plasma Physics, Czech Academy of Sciences, Za Slovenkou 3, Praha8, Czech Republic
Abstract:The present work is devoted to measure the absolute magnetic field produced by different coils in the EGYPTOR tokamak using a calibrated pickup coil. Scaling these measurements in different equations connected with the discharge currents from each supply system are performed. The pickup coil used in the present study is well calibrated with Helmholz coils at the IPP in Prague, Czech Republic. A 0.2% deviation has been found between an evaluation done in the present study and the calibration using Helmholz coils. Experimental measurements of the toroidal magnetic field are in good agreement with calculations to within 2%. Very low values of stray magnetic field components arising from TF and OH coils are recorded which proves that the compensation coils for these components are sufficient.
Keywords:Small tokamaks  EGYPTOR tokamak  pickup coil  magnetic field
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏