首页 | 本学科首页   官方微博 | 高级检索  
     

电厂三级过热器弯管失效分析
引用本文:周翠兰 郭瑞萍. 电厂三级过热器弯管失效分析[J]. 理化检验(物理分册), 1999, 35(5): 225-226
作者姓名:周翠兰 郭瑞萍
作者单位:太原理工大学材料系!太原030024
摘    要:用金相、电镜、光谱分析等手段对三级过热器弯管失效进行了分析。结果表明,晶界处有铬的化合物所析出,具有晶间腐蚀倾向;材质夹杂和多且颗粒较大;奥氏体晶料不均匀,有严重混晶,上述综合因素导致弯管断裂。

关 键 词:过热器 管 混晶 失效分析 电厂锅炉 锅炉

FAILURE ANALYSIS OF THIRD STAGE SUPERHEATER BEND PIPE
Zhou cuilan Guo Ruiping. FAILURE ANALYSIS OF THIRD STAGE SUPERHEATER BEND PIPE[J]. Physical Testing and Chemical Analysis Part A:Physical Testing, 1999, 35(5): 225-226
Authors:Zhou cuilan Guo Ruiping
Affiliation:Taiyuan University of Technology
Abstract:Failure of third stage superheater bend pipe was studied by means of optical metallograph, SEM and spectrometer analysis. The results showed that Cr-contaning compounds in grain boundary, which will cause susceptibility to intergranular corrosion, large amount of inclusions, uneven austinate grain size are main factors caused cracking of bend pipe.
Keywords:Superheater Tube Mixed grain size Failure analysis