摘    要:在磷酸盐缓冲溶液中加热蒸馏三聚氰胺废水样品,逸出的氨被吸收后通过酸碱滴定测定其含量。该 方法抗干扰能力强,准确度高,完全能满足监测三聚氰胺装置废水中氨含量的需要。

关 键 词:  三聚氰胺  废水  蒸馏法  测定

Determination by Distillation of Ammonia Content in Wastewater from Melamine Unit
Cheng Ping.Determination by Distillation of Ammonia Content in Wastewater from Melamine Unit[J].Journal of the Chemical Fertilizer Industry,2004,31(2):57-58.
Authors:Cheng Ping
Abstract:The melamine wastewater sample is distillated in the phosphate buffer solution, the emitted ammonia is absorbed, and its content is determined by acid-alkali titration. This method provides a high degree of interference protection and high accuracy, fully meeting the requirements of monitoring the ammonia content in the wastewater from the melamine unit.